Gas Generator Sets

CAMDA J420GS Gas Generator Set

CAMDA J420GS Gas Generator Set is retained as one product page with 2 brochure-published fuel and rating configurations. Use the configuration table to compare published data, then confirm fuel quality, site conditions and balance-of-plant scope with CAMDA.

Biogas, Natural Gas Fuel
INNIO Jenbacher Engine / platform brand
J420GS Engine / platform
1,500 / 1,800 rpm Rated speed
High Reliability High Efficiency & Lower Emissions Safety Protection

Engineered for Reliable Gas Power

CAMDA J420GS Gas Generator Set is retained as one product page with 2 brochure-published fuel and rating configurations. Use the configuration table to compare published data, then confirm fuel quality, site conditions and balance-of-plant scope with CAMDA.

Published product information is reviewed together with load, site, fuel and interface requirements before final configuration.

Related solutions
Applicable industries

Model configuration data

Available Configurations for CAMDA J420GS Gas Generator Set

One model page contains every published engine and power configuration. Select the configuration that matches the project duty, frequency and fuel requirements.

2 Published configurations
01 J420GS · Natural Gas · 50 Hz J420GS / 1501 kW / 50 Hz Primary
Engine brand
INNIO Jenbacher
Engine model
J420GS
Fuel
Natural Gas
Frequency
50 Hz
Prime power
1501 kW
Detailed specifications for J420GS · Natural Gas · 50 Hz
Parameter Published value
Electrical power 1501
Thermal power 1563
Electrical efficiency 43 %
Thermal efficiency 45 %
Overall efficiency 88 %
NOx emission 500 mg/Nm³
Generator set series Type 4 Series
Cylinder configuration V70°
Cylinder count 20
Bore 145 mm
Stroke 185 mm
Displacement per cylinder 3 L
Total displacement 61 L
Rated speed 1500 rpm
Net weight 14400 kg
Length 7100 mm
Width 1900 mm
Height 2200 mm
Source 2026英文画册.pdf, page 22, Jenbacher Natural Gas generator set technical data sheet, row 7
02 J420GS · Biogas · 50 Hz J420GS / 1501 kW / 50 Hz
Engine brand
INNIO Jenbacher
Engine model
J420GS
Fuel
Biogas
Frequency
50 Hz
Prime power
1501 kW
Detailed specifications for J420GS · Biogas · 50 Hz
Parameter Published value
Electrical power 1501
Thermal power 1515
Electrical efficiency 42 %
Thermal efficiency 43 %
Overall efficiency 85 %
NOx emission 500 mg/Nm³
Generator set series Type 4 Series
Cylinder configuration V70°
Cylinder count 20
Bore 145 mm
Stroke 185 mm
Displacement per cylinder 3 L
Total displacement 61 L
Rated speed 1500 rpm
Net weight 14400 kg
Length 7100 mm
Width 1900 mm
Height 2200 mm
Source 2026英文画册.pdf, page 22, Jenbacher Biogas generator set technical data sheet, row 18

Technical Specifications

Structured published data for CAMDA J420GS Gas Generator Set. Final performance depends on the confirmed project configuration.

Generator Set

Parameter Published value Parameter Published value
Fuel Biogas, Natural Gas Rated speed 1,500 / 1,800 rpm
Cooling system Water-cooled, project-matched heat rejection Starting method 24 V DC electric start
Controller CAMDA integrated genset controller Communications CAN · RS485 · Ethernet · Modbus
Applicable standard ISO 3046 / project requirements Ambient / altitude review Temperature and altitude derating reviewed per project
Engine / platform J420GS Insulation class Class H
Voltage regulation Digital AVR, project configured Engine / platform brand INNIO Jenbacher

Electrical performance

Parameter Published value Parameter Published value
Fuel Biogas, Natural Gas

Application and configuration

Parameter Published value Parameter Published value
Engine / platform brand INNIO Jenbacher

Gas Engine

Parameter Published value Parameter Published value
Engine / platform J420GS Rated speed 1,500 / 1,800 rpm

Alternator

Parameter Published value Parameter Published value
Insulation class Class H Voltage regulation Digital AVR, project configured

Control System

Parameter Published value Parameter Published value
Controller CAMDA integrated genset controller Communications CAN · RS485 · Ethernet · Modbus

Operating Conditions

Parameter Published value Parameter Published value
Cooling system Water-cooled, project-matched heat rejection Starting method 24 V DC electric start
Ambient / altitude review Temperature and altitude derating reviewed per project Applicable standard ISO 3046 / project requirements

Performance Features

Published engineering strengths for this product family and delivery scope.

High Reliability

Mature combustion design, strengthened components and project-matched auxiliaries support durable continuous operation.

High Efficiency & Lower Emissions

Lean combustion, high-energy ignition and optimized air-fuel control support efficient and cleaner gas utilization.

Safety Protection

Independent controls, cylinder monitoring, protection logic and explosion-protection measures support safe operation.

Low Maintenance Cost

Long service intervals, service-friendly parts and mature platforms reduce maintenance effort and lifecycle cost.

Stable Electrical Output

Matched alternator, excitation and AVR performance support parallel operation and dynamic load response.

Remote Monitoring & Control

Load sharing, protection, communications and remote visibility are configured with the plant operating mode.

Available Configurations & Options

Available options remain subject to project and product-series confirmation.

Gas treatment and generator auxiliary system

Gas Controls

  • Grid-parallel controls — Synchronization, protection and plant control integration.

Gas Energy

  • Heat recovery interface — Project-configured hot-water or thermal-recovery interface.

Gas Fuel

  • Gas treatment and regulation — Fuel conditioning, regulation and project balance-of-plant review.
Need a project-specific configuration? Continue to a reviewed inquiry with the operating requirements.
Talk to an Engineer Request Configuration

Technical Downloads

Current published documents are delivered through their approved access rules.

Planning a Gas Power Generation Project

A practical sequence for defining fuel, electrical duty, site, balance-of-plant, heat use and lifecycle responsibilities before a gas-power proposal.

Download

Gas Quality and Generator Project Review

The gas composition, pressure, contaminants and variability data needed to select a generator and define preprocessing safely.

Download

CAMDA Gas Generator Brochure 2025

PDF · 2025.1

Download

Required fields are marked with an asterisk.

Build the Right Gas Power System for Your Project

From selection and configuration to installation and commissioning.

Talk to an Engineer Explore Gas Generator Sets +86-769-88989999