Diesel Generator Sets

CAMDA KDGP40S Diesel Generator Set

CAMDA KDGP40S Diesel Generator Set is retained as one product page with 1 brochure-published engine and rating configuration. Use the configuration table to compare published data, then confirm site derating, electrical duty and package scope with CAMDA.

Diesel Fuel
Perkins Engine / platform brand
1103A-33TG1 Engine / platform
1,500 / 1,800 rpm Rated speed
Fast Start & Load Acceptance Low Fuel Consumption Stable Voltage & Frequency

Reliable Power When It Matters Most

CAMDA KDGP40S Diesel Generator Set is retained as one product page with 1 brochure-published engine and rating configuration. Use the configuration table to compare published data, then confirm site derating, electrical duty and package scope with CAMDA.

Published product information is reviewed together with load, site, fuel and interface requirements before final configuration.

Applicable industries

Model configuration data

Available Configurations for CAMDA KDGP40S Diesel Generator Set

One model page contains every published engine and power configuration. Select the configuration that matches the project duty, frequency and fuel requirements.

1 Published configuration
01 1103A-33TG1 · Diesel · 50 Hz 1103A-33TG1 / 50 kVA / 50 Hz Primary
Engine brand
Perkins
Engine model
1103A-33TG1
Fuel
Diesel
Frequency
50 Hz
Standby power
50 kVA
Prime power
45 kVA
Detailed specifications for 1103A-33TG1 · Diesel · 50 Hz
Parameter Published value
Diesel consumption 10.7 L/h
Lube oil consumption ≤0.2 g/kWh
Noise ≤92 dBA
Cylinder configuration 3L
Bore 105 mm
Stroke 127 mm
Displacement 3 L
Compression ratio 17.25 : 1
Governor type Electronic
Aspiration method Turbocharged
Starting voltage 12 V
Lube oil capacity 8 L
Coolant capacity 10 L
Net weight 730 kg
Length 1600 mm
Width 720 mm
Height 1180 mm
Source 2026英文画册.pdf, page 11, Perkins 50 Hz technical specifications, row 6

Technical Specifications

Structured published data for CAMDA KDGP40S Diesel Generator Set. Final performance depends on the confirmed project configuration.

Generator Set

Parameter Published value Parameter Published value
Fuel Diesel Rated speed 1,500 / 1,800 rpm
Cooling system Water-cooled, project-matched heat rejection Starting method 24 V DC electric start
Controller CAMDA integrated genset controller Communications CAN · RS485 · Ethernet · Modbus
Applicable standard ISO 8528 / project requirements Ambient / altitude review Temperature and altitude derating reviewed per project
Engine / platform 1103A-33TG1 Insulation class Class H
Voltage regulation Digital AVR, project configured Engine / platform brand Perkins

Electrical performance

Parameter Published value Parameter Published value
Fuel Diesel

Application and configuration

Parameter Published value Parameter Published value
Engine / platform brand Perkins

Diesel Engine

Parameter Published value Parameter Published value
Engine / platform 1103A-33TG1 Rated speed 1,500 / 1,800 rpm

Alternator

Parameter Published value Parameter Published value
Insulation class Class H Voltage regulation Digital AVR, project configured

Control System

Parameter Published value Parameter Published value
Controller CAMDA integrated genset controller Communications CAN · RS485 · Ethernet · Modbus

Operating Conditions

Parameter Published value Parameter Published value
Cooling system Water-cooled, project-matched heat rejection Starting method 24 V DC electric start
Ambient / altitude review Temperature and altitude derating reviewed per project Applicable standard ISO 8528 / project requirements

Performance & Reliability

Published engineering strengths for this product family and delivery scope.

Fast Start & Load Acceptance

Rapid start, stable load acceptance and coordinated controls support standby and prime-power duties.

Low Fuel Consumption

Engine and system matching are configured to reduce fuel use and operating cost for the defined duty.

Stable Voltage & Frequency

Electronic speed regulation, AVR and coordinated protection maintain dependable electrical output under changing loads.

Heavy-Duty Durability

Industrial components, protected packaging and controlled production support demanding environments and long service life.

Remote Monitoring

Controller and optional HMI or SCADA interfaces provide alarms, operating visibility and remote support paths.

Easy Maintenance

Service access, common parts, planned maintenance and lifecycle support simplify upkeep and reduce downtime.

Configurations & Options

Available options remain subject to project and product-series confirmation.

Perkins diesel generator set from the CAMDA brochure

Diesel Controls

  • Transfer and synchronization controls — Automatic transfer, synchronization and remote monitoring integration.

Diesel Package

  • Diesel enclosure and acoustic package — Open, enclosed and project-specific containerized package options.

Diesel Service

  • Diesel lifecycle service scope — Commissioning, training, maintenance planning and parts support.
Need a project-specific configuration? Continue to a reviewed inquiry with the operating requirements.
Talk to an Engineer Request Configuration

Technical Downloads

Current published documents are delivered through their approved access rules.

Generator Selection: Gas, Diesel and Integrated Systems

A structured comparison of diesel, gas and integrated generator systems based on duty, fuel, load behavior, site constraints and lifecycle needs.

Download

How to Size a Generator Set for Critical Loads

A reviewed guide to load definition, starting behavior, operating duty, site conditions and resilience inputs for critical-load generator selection.

Download

CAMDA Diesel Power Solution

PDF · 2025.1

Download

Required fields are marked with an asterisk.

Build the Right Diesel Power System for Your Project

From selection and configuration to installation and commissioning.

Talk to an Engineer Explore Diesel Generator Sets +86-769-88989999